Team Status Report for 11/08/2025

Accomplishments

  • System Integration: Completed integration of all major components, including pump, heaters, fan, sensors, and servos
    • Verified basic operation of each subsystem
    • Integrated Pi 5 and Pico code for synchronized control commands for SSR, fan, and pump through UART
  • SSR Calibration: Used oscilloscope testing to characterize relationship between PWM duty cycle and power output

    Using Oscilloscope to Measure Vrms of SSR Output to Resistors
  • Data Collection Pipeline: Completed logging of temperature, RPM, and power data from sensors and Pi 5 commands into InfluxDB

    Grafana Dashboard of Temperature Readings
  • Started preliminary data collection using constant power hold tests (20-40W)
  • Flow Calibration: Mapped duty cycle values to flow reduction rate %
    • Used oscilloscope to debug flowmeter reading problems

      Using Oscilloscope to Measure Flowmeter Output to RPi5 Input GPIO Signal

Significant Risks

  • Limited Data Collection Time: With only a few weeks left in the semester, there is limited time to gather a large enough dataset for ML model training
    • Risk mitigation: Run automated, continuous overnight tests and streamline test sequencing to maximize data volume
  • Power Supply Limitations: Current power supply does not provide enough wattage for full-load operation
    • Risk mitigation: Acquiring a second power supply with higher capacity to support higher power testing

Design Changes

  • No major design changes this week

Schedule Changes

  • Schedule adjusted to allow additional time for data collection
  • Project remains on track, with initial data collection underway

Leave a Reply