{"id":149,"date":"2024-04-07T03:10:23","date_gmt":"2024-04-07T03:10:23","guid":{"rendered":"http:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/?p=149"},"modified":"2024-04-07T03:15:31","modified_gmt":"2024-04-07T03:15:31","slug":"elijah-knupps-status-report-for-april-6th","status":"publish","type":"post","link":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/2024\/04\/07\/elijah-knupps-status-report-for-april-6th\/","title":{"rendered":"Elijah Knupp\u2019s status report for April 6th"},"content":{"rendered":"<p><b>This week&#8217;s accomplishments<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Attended mandatory labs<\/span>\n<ul>\n<li>Demonstrated my portion of the project to Prof. Fedder and the TAs, received positive feedback<\/li>\n<\/ul>\n<\/li>\n<li>Added a manual taring feature the user can trigger at any time to zero the scale<\/li>\n<li>Completed the Arduino&#8217;s script for the temperature probe, scale, heater, and PID loop\n<ul>\n<li>sends serial data from the temperature probe and scale<\/li>\n<li>sends a confirmation signal back to the rpi that the change it requested from the PID loop was implemented<\/li>\n<li>receives serial input\n<ul>\n<li>user can send a signal to manually tare the scale<\/li>\n<li>receives signals from the rpi-implemented PID loop and turns the water heater on and off wrt to the signal&#8217;s value<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Began testing the PID loop to control the heating element\n<ul>\n<li>Very close to being fully implemented\n<ul>\n<li>currently, the loop overshoots the target temperature by around 2-3 degrees\u00a0Fahrenheit<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><b>Next weeks plan<\/b><\/p>\n<ul>\n<li>Implement the pump into the project.\n<ul>\n<li>will need to ensure the pump&#8217;s flow rate are accurate per the user&#8217;s request\n<ul>\n<li>see testing plan below<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Finish testing and verifying the PID loop for the heating element\n<ul>\n<li>see testing plan below<\/li>\n<\/ul>\n<\/li>\n<li>begin fabricating all of the different components on to the 3-D printer&#8217;s frame\n<ul>\n<li>will need to 3-D print a mount for the water pump. Will be placed on the very top of the frame.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><b>Status Report: <\/b><span style=\"font-weight: 400\">On schedule<\/span><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center\"><em><b>Verification and Validation<\/b><\/em><\/p>\n<ul>\n<li>Verification:\n<ul>\n<li>Heating element: As per the design project report, we aim to deliver water within +-5 degrees Fahrenheit of what the user specifies. Mentioned above, we are currently overshooting the temperature by only a couple of degrees. However, this may be necessary due to thermal loss whilst the water travels through the lines, as this temperature reading was taken inside the water heater.\n<ul>\n<li>TEST\n<ul>\n<li>Need to test the FULL range of temperatures the user can request (from around 180 &#8211; 212 degrees Fahrenheit)\n<ul>\n<li>Every 4 degrees (180, 184, &#8230; 212), will ensure that the temperature of the water\u00a0<em>hits the coffee grounds\u00a0<\/em>at +-5 degrees from the users request (although we will shoot for +-3 degrees)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Scale\n<ul>\n<li>Testing will be simple. The user will be using the integrated scale to check the amount of coffee grounds they have placed into the filter\n<ul>\n<li>TEST\n<ul>\n<li>Need to test the full range of weights of coffee grounds the user may use (around 10 &#8211; 40 grams of coffee grounds)\n<ul>\n<li>Every 5 grams, use a known weight to ensure the weight readings are accurate<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Validation\n<ul>\n<li>The water system needs to be safe and intuitive for the user. Whilst the software side is being handled by Rio, I will need to make sure that user can easily and SAFELY handle the water system. I will need to ensure that there are no exposed wires or electronics that could be exposed and damaged if some water is spilled around our machine.\n<ul>\n<li>As of now, the user will need to unscrew the cap of the water heater (which is a converted electric kettle), which will have the temperature probe and tubing attached to this.\n<ul>\n<li>TEST:\n<ul>\n<li>I will ask several individuals to screw and unscrew the lid to ensure ease of use and durability of system.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Cable management is a major component of this as well. I will need to make sure that no wires could jar loose or come exposed.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This week&#8217;s accomplishments Attended mandatory labs Demonstrated my portion of the project to Prof. Fedder and the TAs, received positive feedback Added a manual taring feature the user can trigger at any time to zero the scale Completed the Arduino&#8217;s script for the temperature probe, scale, heater, and PID loop sends serial data from the &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/2024\/04\/07\/elijah-knupps-status-report-for-april-6th\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Elijah Knupp\u2019s status report for April 6th&#8221;<\/span><\/a><\/p>\n","protected":false},"author":877,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[5],"tags":[2],"_links":{"self":[{"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/posts\/149"}],"collection":[{"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/users\/877"}],"replies":[{"embeddable":true,"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/comments?post=149"}],"version-history":[{"count":3,"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/posts\/149\/revisions"}],"predecessor-version":[{"id":153,"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/posts\/149\/revisions\/153"}],"wp:attachment":[{"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/media?parent=149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/categories?post=149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/course.ece.cmu.edu\/~ece500\/projects\/s24-teama1\/wp-json\/wp\/v2\/tags?post=149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}